Applications
For use in closed environments or populated spaces such as auditoriums, arenas and health facilities where more stringent customer specifications for smoke and halogen-free materials are desired. Ideally suited for use in a broad range of commercial, industrial and utility applications where reliability is a major concern, where maximum performance will be demanded and where space is limited. For use in free air, raceways or direct burial in accordance with NEC
Construction
Conductor: 14 AWG thru 1000 kcmil compressed tinned copper per ASTM B33, Class B stranding per ASTM B8
Insulation: Composite Low-Smoke, Zero-Halogen Cross-linked Polyolefin (LSZH XLPO) colored for contrast with black Low-Smoke, Zero-Halogen Cross-linked Polyolefin (LSZH XLPO)
Print: AMERICAN WIRE GROUP LSZH TYPE USE-2 OR RHH OR RHW-2 (SIZE) 600 V OIL RES I SUN RES -40C ST1* FOR CT USE* (UL) DAY/MONTH/YEAR OF MFG SEQUENTIALFOOTAGE MARK * “ST1” and “FOR CT USE” on 1/0 AWG and larger.
Features
- Rated at 90°C wet or dry
- Low-Smoke, Zero-Halogen insulation systemExtra-tough, mechanically rugged composite insulation construction
- Low Friction for easy pulling on 8 AWG and larger
- Excellent electrical, thermal and physical properties
- Excellent moisture resistance, exceeding UL 44 requirements
- Excellent resistance to crush, compression cuts and heat deformation
- Excellent flame resistance
- Resistant to most oils and chemicals
- UV/sunlight-resistant
- Rated ST-1 for Limited Smoke per UL 44 on sizes 1/0 AWG and larger
- Stable electrical properties over a broad temperature range
- Excellent low temperature cold bend characteristics, meets cold bend and cold impact test at -40°C
Compliances:
- National Electrical Code (NEC)
- “FOR CT USE” on 1/0 AWG and larger in accordance with NEC
- UL 44 Type RHH/RHW-2
- UL 854 Type USE-2
- Limited Smoke rating per UL 44 and UL 1685
- Compressed tinned copper per ASTM B33
- Class B stranding per ASTM B8
- ICEA T-33-655 smoke, halogen and acid gas requirements
- ICEA S-95-658/NEMA WC70
Flame Test Compliances:
- For 1/0 AWG and larger: IEEE 383, IEEE 1202/CSA FT4
- UL 1685
Other Compliances:
- EPA 40 CFR, Part 261 for leachable lead content per TCLP
- OSHA Acceptable
- RoHS Compliant
Packaging: Material cut to length and shipped on non-returnable wood reels
Options:
- 2 kV version
- Bare copper conductor
- Other stranding available
Items |
/Asset/lzsh-image.png 14-01XLSOH LSZH XLPO/LSZH XLPO, Unshielded 600V, UL Type RHH/RHW-2/USE-2 |
/Asset/lzsh-image.png 12-01XLSOH LSZH XLPO/LSZH XLPO, Unshielded 600V, UL Type RHH/RHW-2/USE-2 |
/Asset/lzsh-image.png 10-01XLSOH LSZH XLPO/LSZH XLPO, Unshielded 600V, UL Type RHH/RHW-2/USE-2 |
/Asset/lzsh-image.png 8-01XLSOH LSZH XLPO/LSZH XLPO, Unshielded 600V, UL Type RHH/RHW-2/USE-2 |
/Asset/lzsh-image.png 6-01XLSOH LSZH XLPO/LSZH XLPO, Unshielded 600V, UL Type RHH/RHW-2/USE-2 |
|||||
Size AWG or KCMIL |
N/A 14 | N/A 12 | N/A 10 | N/A 8 | N/A 6 | |||||
Insulation Thickness (mil) |
N/A 7/.0242 | N/A 7/.0305 | N/A 7/.0385 | N/A 7/.0486 | N/A 7/.0612 | |||||
Nominal Conductor Diameter (in) |
N/A 0.07 | N/A 0.09 | N/A 0.12 | N/A 0.15 | N/A 0.18 | |||||
Nominal Conductor Diameter (mm) |
N/A 1.78 | N/A 2.29 | N/A 3.05 | N/A 3.81 | N/A 4.57 | |||||
Minimum Average Insulation Thickness (in) |
N/A 0.030 | N/A 0.030 | N/A 0.030 | N/A 0.045 | N/A 0.045 | |||||
Minimum Average Insulation Diameter (in) |
N/A 0.14 | N/A 0.16 | N/A 0.18 | N/A 0.24 | N/A 0.28 | |||||
Minimum Average Insulation Diameter (mm) |
N/A 3.56 | N/A 4.06 | N/A 4.57 | N/A 6.10 | N/A 7.11 | |||||
Minimum Average Jackness Thickness (in) |
N/A 0.015 | N/A 0.015 | N/A 0.015 | N/A 0.015 | N/A 0.030 | |||||
Minimum Average Jackness Thickness (mm) |
N/A 0.38 | N/A 0.38 | N/A 0.38 | N/A 0.38 | N/A 0.76 | |||||
Minimum Average Jackness Diameter (in) |
N/A 0.17 | N/A 0.19 | N/A 0.21 | N/A 0.28 | N/A 0.35 | |||||
Minimum Average Jackness Diameter (mm) |
N/A 4.32 | N/A 4.83 | N/A 5.33 | N/A 7.11 | N/A 8.89 | |||||
Copper Weight (lb/MFT) |
N/A 13 | N/A 20 | N/A 32 | N/A 50 | N/A 81 | |||||
Copper Weight (kg/km) |
N/A 19 | N/A 30 | N/A 48 | N/A 75 | N/A 121 | |||||
Net Weight (lb/MFT) |
N/A 24 | N/A 33 | N/A 48 | N/A 77 | N/A 122 | |||||
Net Weight (kg/km) |
N/A 36 | N/A 49 | N/A 71 | N/A 115 | N/A 182 | |||||
|