Triplex Service Drop Aluminum Conductors - AAC Neutral Messenger
Triplex Service Drop Aluminum Conductor
Applications
To supply power from the utility's lines to the consumer's weatherhead. For service at 600 volts or less (phase to phase) at a conductor temperature of 75 ºC maximum for polyethylene Insulation or 90 ºC maximum for crosslinked insulation.
Construction
Concentric strand or compressed 1350-H19 conductor, polyethylene or crosslinked polyethylene insulation, concentric strand AAC neutral messenger.
Standards
To supply power from the utility's lines to the consumer's weatherhead. For service at 600 volts or less (phase to phase) at a conductor temperature of 75 ºC maximum for polyethylene Insulation or 90 ºC maximum for crosslinked insulation.
Construction
Concentric strand or compressed 1350-H19 conductor, polyethylene or crosslinked polyethylene insulation, concentric strand AAC neutral messenger.
Standards
- B-230 Aluminum Wire 1350-H19 for Electrical Purposes.
- B-231 Aluminum Conductors, Concentric-Lay-Stranded.
- B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
- B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.
- B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
- Triplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA body S-76-474.
Unit of Measure
Items |
/Asset/TRIPLEX-SERVCE-DROP--2-.jpg Haiotis Triplex Service Drop Aluminum Conductors - AAC Neutral Messenger |
/Asset/TRIPLEX-SERVCE-DROP--2-.jpg Patella Triplex Service Drop Aluminum Conductors - AAC Neutral Messenger |
/Asset/TRIPLEX-SERVCE-DROP--2-.jpg Fusus Triplex Service Drop Aluminum Conductors - AAC Neutral Messenger |
/Asset/TRIPLEX-SERVCE-DROP--2-.jpg Oyster Triplex Service Drop Aluminum Conductors - AAC Neutral Messenger |
/Asset/TRIPLEX-SERVCE-DROP--2-.jpg Clam Triplex Service Drop Aluminum Conductors - AAC Neutral Messenger |
|||||
Phase Conductor Size/AWG |
N/A 6 | N/A 6 | N/A 4 | N/A 4 | N/A 2 | |||||
Phase Conductor Stranding |
N/A Solid | N/A 7/w | N/A Solid | N/A 7/w | N/A 7/w | |||||
Phase Conductor Insulation Thickness |
N/A 45 mls | |||||||||
Bare Neutral Messenger Size/AWG |
N/A 6 | N/A 6 | N/A 4 | N/A 4 | N/A 2 | |||||
Bare Neutral Messenger Stranding |
N/A 7 | |||||||||
Bare Neutral Messenger Breaking Strength |
N/A 563 Lbs | N/A 563 Lbs | N/A 881 Lbs | N/A 881 Lbs | N/A 1350 Lbs | |||||
Weight Per (lb/1000 ft) XLP |
N/A 102.5 Lbs | N/A 109.1 Lbs | N/A 151.9 Lbs | N/A 161.8 Lbs | N/A 243.2 Lbs | |||||
Weight (lb/1000 ft) Poly |
N/A 98.8 Lbs | N/A 101.6 Lbs | N/A 147.6 Lbs | N/A 151.7 Lbs | N/A 229.2 Lbs | |||||
Ampacity XLP |
N/A 85 Amps | N/A 85 Amps | N/A 115 Amps | N/A 115 Amps | N/A 150 Amps | |||||
Ampacity Poly |
N/A 70 Amps | N/A 70 Amps | N/A 90 Amps | N/A 90 Amps | N/A 120 Amps | |||||
|