Triplex Service Drop Aluminum Conductors - ACSR Reduced Size Messenger
Triplex Service Drop Aluminum Conductor
Applications
To supply power from the utility's lines to the consumer's weatherhead. For service at 600 volts or less (phase to phase) at a conductor temperature of 75 ºC maximum for polyethylene Insulation or 90 ºC maximum for crosslinked insulation.
Construction
Concentric strand or compressed 1350-H19 conductor, polyethylene or crosslinked polyethylene insulation, concentric strand ACSR neutral messenger.
Standards
To supply power from the utility's lines to the consumer's weatherhead. For service at 600 volts or less (phase to phase) at a conductor temperature of 75 ºC maximum for polyethylene Insulation or 90 ºC maximum for crosslinked insulation.
Construction
Concentric strand or compressed 1350-H19 conductor, polyethylene or crosslinked polyethylene insulation, concentric strand ACSR neutral messenger.
Standards
- B-230 Aluminum Wire 1350-H19 for Electrical Purposes.
- B-231 Aluminum Conductors, Concentric-Lay-Stranded
- B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
- B-309 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.
- B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
- Triplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA body S-76-474.
Unit of Measure
Items |
/Asset/TRIPLEX-SERVCE-DROP--2-.jpg Scallop Triplex Service Drop Aluminum Conductors - ACSR Reduced Size Messenger |
/Asset/TRIPLEX-SERVCE-DROP--2-.jpg Strombus Triplex Service Drop Aluminum Conductors - ACSR Reduced Size Messenger |
/Asset/TRIPLEX-SERVCE-DROP--2-.jpg Cockle Triplex Service Drop Aluminum Conductors - ACSR Reduced Size Messenger |
/Asset/TRIPLEX-SERVCE-DROP--2-.jpg Janthina Triplex Service Drop Aluminum Conductors - ACSR Reduced Size Messenger |
/Asset/TRIPLEX-SERVCE-DROP--2-.jpg Ranella Triplex Service Drop Aluminum Conductors - ACSR Reduced Size Messenger |
|||||
Phase Conductor Size/AWG |
N/A 4 | N/A 4 | N/A 2 | N/A 1/0 | N/A 1/0 | |||||
Phase Conductor Stranding |
N/A Solid | N/A 7/w | N/A 7/w | N/A 7/w | N/A 19/w | |||||
Phase Conductor Insulation Thickness |
N/A 45 mls | N/A 45 mls | N/A 45 mls | N/A 60 mls | N/A 60 mls | |||||
Bare Neutral Messenger Size/AWG |
N/A 6 | N/A 6 | N/A 4 | N/A 2 | N/A 2 | |||||
Bare Neutral Messenger Stranding |
N/A 6/1 | |||||||||
Bare Neutral Messenger Breaking Strength |
N/A 1190 Lbs | N/A 1190 Lbs | N/A 1860 Lbs | N/A 2850 Lbs | N/A 2850 Lbs | |||||
Weight Per (lb/1000 ft) XLP |
N/A 148 Lbs | N/A 158 Lbs | N/A 233 Lbs | N/A 376 Lbs | N/A 372 Lbs | |||||
Weight (lb/1000 ft) Poly |
N/A 144 Lbs | N/A 148 Lbs | N/A 227 Lbs | N/A 365 Lbs | N/A 362 Lbs | |||||
Ampacity XLP |
N/A 115 Amps | N/A 115 Amps | N/A 150 Amps | N/A 205 Amps | N/A 205 Amps | |||||
Ampacity Poly |
N/A 90 Amps | N/A 90 Amps | N/A 120 Amps | N/A 160 Amps | N/A 160 Amps | |||||
|