Triplex Service Drop Aluminum Conductor - AAAC 6201 Alloy Reduced Size Neutral Messenger
Triplex Service Drop Aluminum Conductor
Applications
To supply power from the utility's lines to the consumer's weatherhead. For service at 600 volts or less (phase to phase) at a conductor temperature of 75 ºC maximum for polyethylene Insulation or 90 ºC maximum for crosslinked insulation.
Construction
Concentric strand or compressed 1350-H19 conductor, polyethylene or crosslinked polyethylene insulation, concentric strand 6201 alloy neutral messenger.
Standards
To supply power from the utility's lines to the consumer's weatherhead. For service at 600 volts or less (phase to phase) at a conductor temperature of 75 ºC maximum for polyethylene Insulation or 90 ºC maximum for crosslinked insulation.
Construction
Concentric strand or compressed 1350-H19 conductor, polyethylene or crosslinked polyethylene insulation, concentric strand 6201 alloy neutral messenger.
Standards
- B-230 Aluminum Wire 1350-H19 for Electrical Purposes.
- B-231 Aluminum Conductors, Concentric-Lay-Stranded.
- B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
- B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.
- B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
- Triplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA body S-76-474
Unit of Measure
Items |
/Asset/TRIPLEX-SERVCE-DROP--2-.jpg Artemia Triplex Service Drop Aluminum Conductor - AAAC 6201 Alloy Reduced Size Neutral Messenger |
/Asset/TRIPLEX-SERVCE-DROP--2-.jpg Crab Triplex Service Drop Aluminum Conductor - AAAC 6201 Alloy Reduced Size Neutral Messenger |
/Asset/TRIPLEX-SERVCE-DROP--2-.jpg Solaster Triplex Service Drop Aluminum Conductor - AAAC 6201 Alloy Reduced Size Neutral Messenger |
/Asset/TRIPLEX-SERVCE-DROP--2-.jpg Sandcrab Triplex Service Drop Aluminum Conductor - AAAC 6201 Alloy Reduced Size Neutral Messenger |
/Asset/TRIPLEX-SERVCE-DROP--2-.jpg Echinus Triplex Service Drop Aluminum Conductor - AAAC 6201 Alloy Reduced Size Neutral Messenger |
|||||
Phase Conductor Size/AWG |
N/A 4 | N/A 4 | N/A 2 | N/A 1/0 | N/A 1/0 | |||||
Phase Conductor Stranding |
N/A Solid | N/A 7 | N/A 7 | N/A 7 | N/A 19 | |||||
Phase Conductor Insulation Thickness |
N/A 45 mls | N/A 45 mls | N/A 45 mls | N/A 60 mls | N/A 60 mls | |||||
Bare Neutral Messenger Size/AWG |
N/A 6 | N/A 6 | N/A 4 | N/A 2 | N/A 2 | |||||
Bare Neutral Messenger Stranding |
N/A 7 | |||||||||
Bare Neutral Messenger Breaking Strength |
N/A 1110 Lbs | N/A 1110 Lbs | N/A 1760 Lbs | N/A 2800 Lbs | N/A 2800 Lbs | |||||
Weight Per (lb/1000 ft) XLP |
N/A 141.4 Lbs | N/A 151.3 Lbs | N/A 226.6 Lbs | N/A 368.8 Lbs | N/A 358.8 Lbs | |||||
Weight (lb/1000 ft) Poly |
N/A 137.1 Lbs | N/A 141.2 Lbs | N/A 212.6 Lbs | N/A 343.1 Lbs | N/A 343.1 Lbs | |||||
Ampacity XLP |
N/A 115 Amps | N/A 115 Amps | N/A 150 Amps | N/A 205 Amps | N/A 205 Amps | |||||
Ampacity Poly |
N/A 90 Amps | N/A 90 Amps | N/A 120 Amps | N/A 160 Amps | N/A 160 Amps | |||||
|