SunGuard XLPE Aluminum, Photovoltaic Wire 2 kV, 90°C - PHYSICAL PROPERTIES
SunGuard XLPE Aluminum, Photovoltaic Wire 2kV, 90°C
Applications
Single conductor, sunlight-resistant, photovoltaic wire rated 90 ºC wet or 105ºC dry 2000V for interconnection wiring of grounded and ungrounded photovoltaic power systems as described in Section 690.31(A) and other applicable parts of the National Electrical Code (NEC), NFPA 70. For use in free air, raceways or direct burial in accordance with NEC.
Construction
Conductor:8 AWG thru 1000 kcmil compact aluminum (8000 series)
Insulation: Flame-retardant Cross-Linked Polyethylene (XLPE), black
Options:
Material cut to length and shipped on non-returnable wood reels
Single conductor, sunlight-resistant, photovoltaic wire rated 90 ºC wet or 105ºC dry 2000V for interconnection wiring of grounded and ungrounded photovoltaic power systems as described in Section 690.31(A) and other applicable parts of the National Electrical Code (NEC), NFPA 70. For use in free air, raceways or direct burial in accordance with NEC.
Construction
Conductor:8 AWG thru 1000 kcmil compact aluminum (8000 series)
Insulation: Flame-retardant Cross-Linked Polyethylene (XLPE), black
Options:
- Colored phase ID stripes available on request
- Multiplexing available on request
- UL 1581 VW-1 compliance available on request
- Rated 90ºC wet and dry
- Deformation-resistant at high temperatures
- Excellent moisture resistance, exceeds UL 44
- Stable electrical properties over a broad temperature range
- Excellent resistance to crush and compression cuts
- Resistant to most oils and chemicals
- UV/sunlight-resistant
- Meets cold bend test at -40 ºC
- ASTM B800 - 05(2011) Standard Specification for 8000 Series Aluminum Alloy Wire for Electrical Purposes - Annealed and Intermediate Tempers
- ASTM B801 - 07(2012) Standard Specification for Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy for Subsequent Covering or Insulation
- ASTM B836 - 00(2011) Standard Specification for Compact Round Stranded Aluminum Conductors Using Single Input Wire Construction
- UL 4703 Type PV
- National Electrical Code (NEC)
- ICEA S-95-658/NEMA WC70
- UL 44 Type RHH or RHW-2
Other Compliances
- EPA 40 CFR, Part 261 for leachable lead content per TCLP
- OSHA Acceptable
- RoHS Compliant, Sun Res, Gas and Oil Resistant II
Option
UL 1581 VW-1 compliance available on request
19 strand conductors available on request
Material cut to length and shipped on non-returnable wood reels
AA8000 | ||
Maximum Electrical Resistivity | ||
Temperature | 20℃ | |
AWG size | Ω/1000ft | Ω/1000m |
8 | 1.07 | 3.515 |
7 | 0.8495 | 2.787 |
6 | 0.674 | 2.211 |
5 | 0.5346 | 1.754 |
4 | 0.4238 | 1.39 |
3 | 0.3361 | 1.103 |
2 | 0.2665 | 0.8745 |
1 | 0.2113 | 0.6934 |
1/0 | 0.1676 | 0.5498 |
2/0 | 0.1329 | 0.4361 |
3/0 | 0.1055 | 0.3459 |
4/0 | 0.836 | 0.2743 |
250kmil | 0.07076 | 0.2322 |
300 | 0.05897 | 0.1935 |
350 | 0.05054 | 0.1659 |
400 | 0.04423 | 0.145 |
450 | 0.03931 | 0.1289 |
500 | 0.03537 | 0.1161 |
550 | 0.03216 | 0.1055 |
600 | 0.02948 | 0.09673 |
700 | 0.02527 | 0.08291 |
750 | 0.02358 | 0.07738 |
800 | 0.02211 | 0.07254 |
900 | 0.01966 | 0.06448 |
1000 | 0.01769 | 0.05804 |
Item # |
Conductor
|
Conductor
|
Nominal
|
Minimum
|
Nominal
|
Aluminum
|
Net Cable
|
*Allowable
|
---|---|---|---|---|---|---|---|---|
A8-01PV2X0700* A8-01PV2X0700*/Asset/PV20cable20AL.jpg |
Conductor Size (AWG/kcmil) N/A 8 |
Conductor Stranding N/A 7/.0486 |
Nominal Conductor O.D. inches (mm) N/A 0.1340 (3.40) |
Minimum Average Insulation Thickness inches (mm) N/A 0.0850 (2.16) |
Nominal Cable Diameter inches (mm) N/A 0.3100 (7.87) |
Aluminum Weight lbs/MFT (KG/KM) N/A 16 (23) |
Net Cable Weight lbs/MFT (KG/KM) N/A 52 (78) |
*Allowable Ampacity 90° N/A 45 |
A6-01PV2X0700* A6-01PV2X0700*/Asset/PV20cable20AL.jpg |
Conductor Size (AWG/kcmil) N/A 6 |
Conductor Stranding N/A 7/.0612 |
Nominal Conductor O.D. inches (mm) N/A 0.1690 (4.29) |
Minimum Average Insulation Thickness inches (mm) N/A 0.0850 (2.16) |
Nominal Cable Diameter inches (mm) N/A 0.3450 (8.76) |
Aluminum Weight lbs/MFT (KG/KM) N/A 25 (37) |
Net Cable Weight lbs/MFT (KG/KM) N/A 67 (100) |
*Allowable Ampacity 90° N/A 55 |
A4-01PV2X0700* A4-01PV2X0700*/Asset/PV20cable20AL.jpg |
Conductor Size (AWG/kcmil) N/A 4 |
Conductor Stranding N/A 7/.0772 |
Nominal Conductor O.D. inches (mm) N/A 0.2130 (5.41) |
Minimum Average Insulation Thickness inches (mm) N/A 0.0850 (2.16) |
Nominal Cable Diameter inches (mm) N/A 0.3890 (9.88) |
Aluminum Weight lbs/MFT (KG/KM) N/A 39 (58) |
Net Cable Weight lbs/MFT (KG/KM) N/A 90 (133) |
*Allowable Ampacity 90° N/A 75 |
A2-01PV2X0700* A2-01PV2X0700*/Asset/PV20cable20AL.jpg |
Conductor Size (AWG/kcmil) N/A 2 |
Conductor Stranding N/A 7/.0974 |
Nominal Conductor O.D. inches (mm) N/A 0.2680 (6.81) |
Minimum Average Insulation Thickness inches (mm) N/A 0.0850 (2.16) |
Nominal Cable Diameter inches (mm) N/A 0.4440 (11.28) |
Aluminum Weight lbs/MFT (KG/KM) N/A 63 (93) |
Net Cable Weight lbs/MFT (KG/KM) N/A 122 (182) |
*Allowable Ampacity 90° N/A 100 |
A1-01PV2X1900* A1-01PV2X1900*/Asset/PV20cable20AL.jpg |
Conductor Size (AWG/kcmil) N/A 1 |
Conductor Stranding N/A 19/.0664 |
Nominal Conductor O.D. inches (mm) N/A 0.2990 (7.59) |
Minimum Average Insulation Thickness inches (mm) N/A 0.1050 (2.67) |
Nominal Cable Diameter inches (mm) N/A 0.5150 (13.08) |
Aluminum Weight lbs/MFT (KG/KM) N/A 79 (117) |
Net Cable Weight lbs/MFT (KG/KM) N/A 162 (241) |
*Allowable Ampacity 90° N/A 115 |
A1/0-01PV2X190* A1/0-01PV2X190*/Asset/PV20cable20AL.jpg |
Conductor Size (AWG/kcmil) N/A 1/0 |
Conductor Stranding N/A 19/.0745 |
Nominal Conductor O.D. inches (mm) N/A 0.3360 (8.53) |
Minimum Average Insulation Thickness inches (mm) N/A 0.1050 (2.67) |
Nominal Cable Diameter inches (mm) N/A 0.5520 (14.02) |
Aluminum Weight lbs/MFT (KG/KM) N/A 99 (148) |
Net Cable Weight lbs/MFT (KG/KM) N/A 191 (284) |
*Allowable Ampacity 90° N/A 135 |
A2/0-01PV2X1900* A2/0-01PV2X1900*/Asset/PV20cable20AL.jpg |
Conductor Size (AWG/kcmil) N/A 2/0 |
Conductor Stranding N/A 19/.0837 |
Nominal Conductor O.D. inches (mm) N/A 0.3760 (9.55) |
Minimum Average Insulation Thickness inches (mm) N/A 0.1050 (2.67) |
Nominal Cable Diameter inches (mm) N/A 0.5920 (15.04) |
Aluminum Weight lbs/MFT (KG/KM) N/A 125 (186) |
Net Cable Weight lbs/MFT (KG/KM) N/A 225 (334) |
*Allowable Ampacity 90° N/A 150 |
A3/0-01PV2X1900* A3/0-01PV2X1900*/Asset/PV20cable20AL.jpg |
Conductor Size (AWG/kcmil) N/A 3/0 |
Conductor Stranding N/A 19/.0940 |
Nominal Conductor O.D. inches (mm) N/A 0.4230 (10.74) |
Minimum Average Insulation Thickness inches (mm) N/A 0.1050 (2.67) |
Nominal Cable Diameter inches (mm) N/A 0.6390 (16.23) |
Aluminum Weight lbs/MFT (KG/KM) N/A 158 (235) |
Net Cable Weight lbs/MFT (KG/KM) N/A 267 (398) |
*Allowable Ampacity 90° N/A 175 |
A4/0-01PV2X1900 A4/0-01PV2X1900/Asset/PV20cable20AL.jpg |
Conductor Size (AWG/kcmil) N/A 4/0 |
Conductor Stranding N/A 19/.1055 |
Nominal Conductor O.D. inches (mm) N/A 0.4750 (12.07) |
Minimum Average Insulation Thickness inches (mm) N/A 0.1050 (2.67) |
Nominal Cable Diameter inches (mm) N/A 0.6910 (17.55) |
Aluminum Weight lbs/MFT (KG/KM) N/A 199 (296) |
Net Cable Weight lbs/MFT (KG/KM) N/A 319 (475) |
*Allowable Ampacity 90° N/A 205 |
A250-01PV2X3700 A250-01PV2X3700/Asset/PV20cable20AL.jpg |
Conductor Size (AWG/kcmil) N/A 250 |
Conductor Stranding N/A 37/.0822 |
Nominal Conductor O.D. inches (mm) N/A 0.5200 (13.21) |
Minimum Average Insulation Thickness inches (mm) N/A 0.1200 (3.05) |
Nominal Cable Diameter inches (mm) N/A 0.7660 (19.46) |
Aluminum Weight lbs/MFT (KG/KM) N/A 262 (390) |
Net Cable Weight lbs/MFT (KG/KM) N/A 413 (615) |
*Allowable Ampacity 90° N/A 230 |
A300-01PV2X3700 A300-01PV2X3700/Asset/PV20cable20AL.jpg |
Conductor Size (AWG/kcmil) N/A 300 |
Conductor Stranding N/A 37/.0900 |
Nominal Conductor O.D. inches (mm) N/A 0.5700 (14.48) |
Minimum Average Insulation Thickness inches (mm) N/A 0.1200 (3.05) |
Nominal Cable Diameter inches (mm) N/A 0.8160 (20.73) |
Aluminum Weight lbs/MFT (KG/KM) N/A 282 (420) |
Net Cable Weight lbs/MFT (KG/KM) N/A 445 (663) |
*Allowable Ampacity 90° N/A 260 |
A350-01PV2X3700 A350-01PV2X3700/Asset/PV20cable20AL.jpg |
Conductor Size (AWG/kcmil) N/A 350 |
Conductor Stranding N/A 37/.0972 |
Nominal Conductor O.D. inches (mm) N/A 0.6160 (15.65) |
Minimum Average Insulation Thickness inches (mm) N/A 0.1200 (3.05) |
Nominal Cable Diameter inches (mm) N/A 0.8620 (21.89) |
Aluminum Weight lbs/MFT (KG/KM) N/A 329 (490) |
Net Cable Weight lbs/MFT (KG/KM) N/A 503 (749) |
*Allowable Ampacity 90° N/A 280 |
A400-01PV2X3700 A400-01PV2X3700/Asset/PV20cable20AL.jpg |
Conductor Size (AWG/kcmil) N/A 400 |
Conductor Stranding N/A 37/.1040 |
Nominal Conductor O.D. inches (mm) N/A 0.6590 (16.74) |
Minimum Average Insulation Thickness inches (mm) N/A 0.1200 (3.05) |
Nominal Cable Diameter inches (mm) N/A 0.9050 (22.99) |
Aluminum Weight lbs/MFT (KG/KM) N/A 376 (560) |
Net Cable Weight lbs/MFT (KG/KM) N/A 561 (835) |
*Allowable Ampacity 90° N/A 305 |
A500-01PV2X3700 A500-01PV2X3700/Asset/PV20cable20AL.jpg |
Conductor Size (AWG/kcmil) N/A 500 |
Conductor Stranding N/A 37/.1159 |
Nominal Conductor O.D. inches (mm) N/A 0.7360 (18.69) |
Minimum Average Insulation Thickness inches (mm) N/A 0.1200 (3.05) |
Nominal Cable Diameter inches (mm) N/A 0.9820 (24.94) |
Aluminum Weight lbs/MFT (KG/KM) N/A 471 (701) |
Net Cable Weight lbs/MFT (KG/KM) N/A 675 (1004) |
*Allowable Ampacity 90° N/A 350 |
A600-01PV2X6100* A600-01PV2X6100*/Asset/PV20cable20AL.jpg |
Conductor Size (AWG/kcmil) N/A 600 |
Conductor Stranding N/A 61/.0992 |
Nominal Conductor O.D. inches (mm) N/A 0.8130 (20.65) |
Minimum Average Insulation Thickness inches (mm) N/A 0.1350 (3.43) |
Nominal Cable Diameter inches (mm) N/A 1.0890 (27.66) |
Aluminum Weight lbs/MFT (KG/KM) N/A 565 (841) |
Net Cable Weight lbs/MFT (KG/KM) N/A 818 (1217) |
*Allowable Ampacity 90° N/A 385 |
A750-01PV2X6100* A750-01PV2X6100*/Asset/PV20cable20AL.jpg |
Conductor Size (AWG/kcmil) N/A 750 |
Conductor Stranding N/A 61/.1109 |
Nominal Conductor O.D. inches (mm) N/A 0.9080 (23.06) |
Minimum Average Insulation Thickness inches (mm) N/A 0.1350 (3.43) |
Nominal Cable Diameter inches (mm) N/A 1.1840 (30.07) |
Aluminum Weight lbs/MFT (KG/KM) N/A 706 (1051) |
Net Cable Weight lbs/MFT (KG/KM) N/A 985 (1466) |
*Allowable Ampacity 90° N/A 435 |
A1000-01PV2X6100* A1000-01PV2X6100*/Asset/PV20cable20AL.jpg |
Conductor Size (AWG/kcmil) N/A 1000 |
Conductor Stranding N/A 61/.1280 |
Nominal Conductor O.D. inches (mm) N/A 1.0600 (26.92) |
Minimum Average Insulation Thickness inches (mm) N/A 0.1350 (3.43) |
Nominal Cable Diameter inches (mm) N/A 1.3360 (33.93) |
Aluminum Weight lbs/MFT (KG/KM) N/A 914 (1360) |
Net Cable Weight lbs/MFT (KG/KM) N/A 1235 (1838) |
*Allowable Ampacity 90° N/A 500 |