Tinned Copper - Stranded
Bare and Tinned Copper
Dimensions and weights are nominal values, subject to standard manufacturing tolerances. Conductor ampacities are in accordance with the NEC, latest edition.
Updated 12/6/2021
APPLICATIONS
Used for overhead electrical transmission and distribution lines, grounding electrical systems, electrical test equipment and other infrastructure.
CONSTRUCTION
Conductors: Concentric-lay stranded bare copper conductors available in soft temper only.
Tin Coating: A soft drawn conductor is either hot dipped or electroplated with tin. This process significantly improves corrosion resistance.
STANDARDS
- ASTM B3 - Soft or annealed copper wire
- ASTM B8 - Concentric-lay stranded copper conductors, all tempers
- ASTM B33 - Tinned soft or annealed copper wire
- ASTM B258 - Standard Specification for Standard Nominal Diameters and Cross-Sectional Areas of AWG Sizes of Solid Round Wires Used as Electrical Conductors
- Federal Specification QQ-W-343 - Wire, Electrical, Copper (Uninsulated)
Dimensions and weights are nominal values, subject to standard manufacturing tolerances. Conductor ampacities are in accordance with the NEC, latest edition.
Updated 12/6/2021
Item # |
Size AWG
|
Number
|
Overall
|
Weight
|
Breaking
|
Allowable
|
---|---|---|---|---|---|---|
8-01BC701 8-01BC701/Asset/BARE-COPPER-WIRE-TINNED.jpg |
Size AWG or KCMIL N/A 8 |
Number of Strands N/A 7/w |
Overall Diameter N/A 0.146 Inches |
Weight (lb/1000 ft) N/A 51.0 Lbs |
Breaking Strength Soft N/A 499 Lbs |
Allowable Ampacity N/A 95 Amps |
6-01BC701 6-01BC701/Asset/BARE-COPPER-WIRE-TINNED.jpg |
Size AWG or KCMIL N/A 6 |
Number of Strands N/A 7/w |
Overall Diameter N/A 0.184 Inches |
Weight (lb/1000 ft) N/A 81.1 Lbs |
Breaking Strength Soft N/A 794 Lbs |
Allowable Ampacity N/A 130 Amps |
4-01BC701 4-01BC701/Asset/BARE-COPPER-WIRE-TINNED.jpg |
Size AWG or KCMIL N/A 4 |
Number of Strands N/A 7/w |
Overall Diameter N/A 0.232 Inches |
Weight (lb/1000 ft) N/A 128.9 Lbs |
Breaking Strength Soft N/A 1320 Lbs |
Allowable Ampacity N/A 170 Amps |
3-01BC701 3-01BC701/Asset/BARE-COPPER-WIRE-TINNED.jpg |
Size AWG or KCMIL N/A 3 |
Number of Strands N/A 7/w |
Overall Diameter N/A 0.260 Inches |
Weight (lb/1000 ft) N/A 162.50 Lbs |
Breaking Strength Soft N/A 1670.0 Lbs |
Allowable Ampacity N/A 200 Amps |
2-01BC701 2-01BC701/Asset/BARE-COPPER-WIRE-TINNED.jpg |
Size AWG or KCMIL N/A 2 |
Number of Strands N/A 7/w |
Overall Diameter N/A 0.292 Inches |
Weight (lb/1000 ft) N/A 204.9 Lbs |
Breaking Strength Soft N/A 2110 Lbs |
Allowable Ampacity N/A 230 Amps |
1-01BC701 1-01BC701/Asset/BARE-COPPER-WIRE-TINNED.jpg |
Size AWG or KCMIL N/A 1 |
Number of Strands N/A 7/w |
Overall Diameter N/A 0.332 Inches |
Weight (lb/1000 ft) N/A 258.4 Lbs |
Breaking Strength Soft N/A 2552 Lbs |
Allowable Ampacity N/A 265 Amps |
1/0-01BC701 1/0-01BC701/Asset/BARE-COPPER-WIRE-TINNED.jpg |
Size AWG or KCMIL N/A 1/0 |
Number of Strands N/A 7/w |
Overall Diameter N/A 0.368 Inches |
Weight (lb/1000 ft) N/A 325.8 Lbs |
Breaking Strength Soft N/A 3221 Lbs |
Allowable Ampacity N/A 310 Amps |
1/0-01BC1901 1/0-01BC1901/Asset/BARE-COPPER-WIRE-TINNED.jpg |
Size AWG or KCMIL N/A 1/0 |
Number of Strands N/A 19/w |
Overall Diameter N/A 0.373 Inches |
Weight (lb/1000 ft) N/A 325.8 Lbs |
Breaking Strength Soft N/A 3221 Lbs |
Allowable Ampacity N/A 310 Amps |
2/0-01BC701 2/0-01BC701/Asset/BARE-COPPER-WIRE-TINNED.jpg |
Size AWG or KCMIL N/A 2/0 |
Number of Strands N/A 7/w |
Overall Diameter N/A 0.414 Inches |
Weight (lb/1000 ft) N/A 410.9 Lbs |
Breaking Strength Soft N/A 4062 Lbs |
Allowable Ampacity N/A 355 Amps |
2/0-01BC1901 2/0-01BC1901/Asset/BARE-COPPER-WIRE-TINNED.jpg |
Size AWG or KCMIL N/A 2/0 |
Number of Strands N/A 19/w |
Overall Diameter N/A 0.418 Inches |
Weight (lb/1000 ft) N/A 410.9 Lbs |
Breaking Strength Soft N/A 4062 Lbs |
Allowable Ampacity N/A 355 Amps |
3/0-01BC701 3/0-01BC701/Asset/BARE-COPPER-WIRE-TINNED.jpg |
Size AWG or KCMIL N/A 3/0 |
Number of Strands N/A 7/w |
Overall Diameter N/A 0.464 Inches |
Weight (lb/1000 ft) N/A 518.1 Lbs |
Breaking Strength Soft N/A 5074 Lbs |
Allowable Ampacity N/A 410 Amps |
3/0-01BC1901 3/0-01BC1901/Asset/BARE-COPPER-WIRE-TINNED.jpg |
Size AWG or KCMIL N/A 3/0 |
Number of Strands N/A 19/w |
Overall Diameter N/A 0.470 Inches |
Weight (lb/1000 ft) N/A 518.1 Lbs |
Breaking Strength Soft N/A 5074 Lbs |
Allowable Ampacity N/A 410 Amps |
4/0-01BC701 4/0-01BC701/Asset/BARE-COPPER-WIRE-TINNED.jpg |
Size AWG or KCMIL N/A 4/0 |
Number of Strands N/A 7/w |
Overall Diameter N/A 0.522 Inches |
Weight (lb/1000 ft) N/A 653.3 Lbs |
Breaking Strength Soft N/A 6453 Lbs |
Allowable Ampacity N/A 480 Amps |
4/0-01BC1901 4/0-01BC1901/Asset/BARE-COPPER-WIRE-TINNED.jpg |
Size AWG or KCMIL N/A 4/0 |
Number of Strands N/A 19/w |
Overall Diameter N/A 0.528 Inches |
Weight (lb/1000 ft) N/A 653.3 Lbs |
Breaking Strength Soft N/A 6453 Lbs |
Allowable Ampacity N/A 480 Amps |
250-01BC1901 250-01BC1901/Asset/BARE-COPPER-WIRE-TINNED.jpg |
Size AWG or KCMIL N/A 250 MCM |
Number of Strands N/A 19/w |
Overall Diameter N/A 0.575 Inches |
Weight (lb/1000 ft) N/A 771.9 Lbs |
Breaking Strength Soft N/A 7940 Lbs |
Allowable Ampacity N/A 530 Amps |
301-01BC1901 301-01BC1901/Asset/BARE-COPPER-WIRE-TINNED.jpg |
Size AWG or KCMIL N/A 300 MCM |
Number of Strands N/A 19/w |
Overall Diameter N/A 0.628 Inches |
Weight (lb/1000 ft) N/A 926.3 Lbs |
Breaking Strength Soft N/A 9160 Lbs |
Allowable Ampacity N/A 590 Amps |
350-01BC3701 350-01BC3701/Asset/BARE-COPPER-WIRE-TINNED.jpg |
Size AWG or KCMIL N/A 350 MCM |
Number of Strands N/A 37/w |
Overall Diameter N/A 0.681 Inches |
Weight (lb/1000 ft) N/A 1081.0 Lbs |
Breaking Strength Soft N/A 10580 Lbs |
Allowable Ampacity N/A 650 Amps |
501-01BC3701 501-01BC3701/Asset/BARE-COPPER-WIRE-TINNED.jpg |
Size AWG or KCMIL N/A 500 MCM |
Number of Strands N/A 37/w |
Overall Diameter N/A 0.813 Inches |
Weight (lb/1000 ft) N/A 1544.0 Lbs |
Breaking Strength Soft N/A 15240 Lbs |
Allowable Ampacity N/A 810 Amps |
601-01BC6101 601-01BC6101/Asset/BARE-COPPER-WIRE-TINNED.jpg |
Size AWG or KCMIL N/A 600 MCM |
Number of Strands N/A 61/w |
Overall Diameter N/A 0.893 Inches |
Weight (lb/1000 ft) N/A 1853.0 Lbs |
Breaking Strength Soft N/A 18300 Lbs |
Allowable Ampacity N/A 910 Amps |
750-01BC6101 750-01BC6101/Asset/BARE-COPPER-WIRE-TINNED.jpg |
Size AWG or KCMIL N/A 750 MCM |
Number of Strands N/A 61/w |
Overall Diameter N/A 0.998 Inches |
Weight (lb/1000 ft) N/A 2316.0 Lbs |
Breaking Strength Soft N/A 22890 Lbs |
Allowable Ampacity N/A 1040 Amps |
1000-01BC6101 1000-01BC6101/Asset/BARE-COPPER-WIRE-TINNED.jpg |
Size AWG or KCMIL N/A 1000 MCM |
Number of Strands N/A 61/w |
Overall Diameter N/A 1.152 Inches |
Weight (lb/1000 ft) N/A 3088.0 Lbs |
Breaking Strength Soft N/A 30500 Lbs |
Allowable Ampacity N/A 1240 Amps |