Copper Triplex Service Drop Cable
Triplex Service Drop Cable
Copper Conductor
Copper Conductor
Application
Used to supply power, usually from a pole-mounted transformer, to the user's service head where connection to the service entrance cable is made. Also suitable for installations for street lighting, security lights, and temporary service for construction. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75 ºC for polyethylene insulated conductors and 90 ºC for crosslinked polyethylene (XLP) insulated conductors.
Specifications
Meets or exceeds the following ASTM specifications:
Construction
Conductors are concentrically stranded compressed soft copper insulated with either crosslinked polyethylene, or conventional polyethylene.
Neutral messengers are either solid or concentrically stranded bare hard-drawn copper.
Notes:
Used to supply power, usually from a pole-mounted transformer, to the user's service head where connection to the service entrance cable is made. Also suitable for installations for street lighting, security lights, and temporary service for construction. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75 ºC for polyethylene insulated conductors and 90 ºC for crosslinked polyethylene (XLP) insulated conductors.
Specifications
Meets or exceeds the following ASTM specifications:
- B-1 Hard-Drawn Copper Wire.
- B-3 Soft or Annealed Copper Wire.
- B-8 Concentric-Lay-Stranded Copper Conductors, Hard, Medium-Hard, or Soft.
Construction
Conductors are concentrically stranded compressed soft copper insulated with either crosslinked polyethylene, or conventional polyethylene.
Neutral messengers are either solid or concentrically stranded bare hard-drawn copper.
Notes:
- Code words for XLP insulated products are formed by adding ""XLP"" to the conventional polyethylene code words above (e.g.- Pica/XLP).
- Ampacity figures for black insulation only. Based on conductor temperature of 75 ºC for polyethylene insulated conductors, 90 ºC for XLP insulated conductors, ambient temperature of 40 ºC 2 ft./sec. wind in sun.
Item # |
Phase
|
Phase
|
Phase
|
Neutral
|
Neutral
|
Neutral
|
Nominal
|
Weight
|
Weight
|
Allowable
|
Allowable
|
---|---|---|---|---|---|---|---|---|---|---|---|
Pica Pica/Asset/CU-TRIPLEX-SERVICE-DROP.jpg |
Phase Conductor Size AWG N/A 8 |
Phase Conductor Stranding N/A 7 |
Phase Conductor Cover Thickness (mils) N/A 45 |
Neutral Messenger Size AWG N/A 10 |
Neutral Messenger Stranding N/A 1 |
Neutral Messenger Rated Strength (lbs.) N/A 529 |
Nominal Lay Length (inches) N/A 10.36 |
Weight (lb/1000 ft) XLP N/A 160 |
Weight (lb/1000 ft) Poly N/A 149 |
Allowable Ampacities XLP N/A 85 |
Allowable Ampacities Poly N/A 70 |
Columbian Columbian/Asset/CU-TRIPLEX-SERVICE-DROP.jpg |
Phase Conductor Size AWG N/A 8 |
Phase Conductor Stranding N/A 1 |
Phase Conductor Cover Thickness (mils) N/A 45 |
Neutral Messenger Size AWG N/A 8 |
Neutral Messenger Stranding N/A 1 |
Neutral Messenger Rated Strength (lbs.) N/A 826 |
Nominal Lay Length (inches) N/A 10.36 |
Weight (lb/1000 ft) XLP N/A 174 |
Weight (lb/1000 ft) Poly N/A 164 |
Allowable Ampacities XLP N/A 85 |
Allowable Ampacities Poly N/A 70 |
Bodoni Bodoni/Asset/CU-TRIPLEX-SERVICE-DROP.jpg |
Phase Conductor Size AWG N/A 8 |
Phase Conductor Stranding N/A 7 |
Phase Conductor Cover Thickness (mils) N/A 45 |
Neutral Messenger Size AWG N/A 8 |
Neutral Messenger Stranding N/A 1 |
Neutral Messenger Rated Strength (lbs.) N/A 826 |
Nominal Lay Length (inches) N/A 10.36 |
Weight (lb/1000 ft) XLP N/A 179 |
Weight (lb/1000 ft) Poly N/A 167 |
Allowable Ampacities XLP N/A 85 |
Allowable Ampacities Poly N/A 70 |
Garamond Garamond/Asset/CU-TRIPLEX-SERVICE-DROP.jpg |
Phase Conductor Size AWG N/A 8 |
Phase Conductor Stranding N/A 7 |
Phase Conductor Cover Thickness (mils) N/A 45 |
Neutral Messenger Size AWG N/A 8 |
Neutral Messenger Stranding N/A 7 |
Neutral Messenger Rated Strength (lbs.) N/A 777 |
Nominal Lay Length (inches) N/A 10.36 |
Weight (lb/1000 ft) XLP N/A 180 |
Weight (lb/1000 ft) Poly N/A 169 |
Allowable Ampacities XLP N/A 85 |
Allowable Ampacities Poly N/A 70 |
Tudor Tudor/Asset/CU-TRIPLEX-SERVICE-DROP.jpg |
Phase Conductor Size AWG N/A 6 |
Phase Conductor Stranding N/A 7 |
Phase Conductor Cover Thickness (mils) N/A 45 |
Neutral Messenger Size AWG N/A 8 |
Neutral Messenger Stranding N/A 1 |
Neutral Messenger Rated Strength (lbs.) N/A 826 |
Nominal Lay Length (inches) N/A 14.88 |
Weight (lb/1000 ft) XLP N/A 246 |
Weight (lb/1000 ft) Poly N/A 232 |
Allowable Ampacities XLP N/A 110 |
Allowable Ampacities Poly N/A 90 |
Futura Futura/Asset/CU-TRIPLEX-SERVICE-DROP.jpg |
Phase Conductor Size AWG N/A 6 |
Phase Conductor Stranding N/A 7 |
Phase Conductor Cover Thickness (mils) N/A 45 |
Neutral Messenger Size AWG N/A 6 |
Neutral Messenger Stranding N/A 1 |
Neutral Messenger Rated Strength (lbs.) N/A 1280 |
Nominal Lay Length (inches) N/A 14.88 |
Weight (lb/1000 ft) XLP N/A 276 |
Weight (lb/1000 ft) Poly N/A 262 |
Allowable Ampacities XLP N/A 110 |
Allowable Ampacities Poly N/A 90 |
Gothic Gothic/Asset/CU-TRIPLEX-SERVICE-DROP.jpg |
Phase Conductor Size AWG N/A 6 |
Phase Conductor Stranding N/A 7 |
Phase Conductor Cover Thickness (mils) N/A 45 |
Neutral Messenger Size AWG N/A 6 |
Neutral Messenger Stranding N/A 7 |
Neutral Messenger Rated Strength (lbs.) N/A 1228 |
Nominal Lay Length (inches) N/A 14.88 |
Weight (lb/1000 ft) XLP N/A 278 |
Weight (lb/1000 ft) Poly N/A 263 |
Allowable Ampacities XLP N/A 110 |
Allowable Ampacities Poly N/A 90 |
Nonpareil Nonpareil/Asset/CU-TRIPLEX-SERVICE-DROP.jpg |
Phase Conductor Size AWG N/A 4 |
Phase Conductor Stranding N/A 7 |
Phase Conductor Cover Thickness (mils) N/A 45 |
Neutral Messenger Size AWG N/A 6 |
Neutral Messenger Stranding N/A 1 |
Neutral Messenger Rated Strength (lbs.) N/A 1280 |
Nominal Lay Length (inches) N/A 14.88 |
Weight (lb/1000 ft) XLP N/A 381 |
Weight (lb/1000 ft) Poly N/A 363 |
Allowable Ampacities XLP N/A 145 |
Allowable Ampacities Poly N/A 115 |
Ionic Ionic/Asset/CU-TRIPLEX-SERVICE-DROP.jpg |
Phase Conductor Size AWG N/A 4 |
Phase Conductor Stranding N/A 7 |
Phase Conductor Cover Thickness (mils) N/A 45 |
Neutral Messenger Size AWG N/A 4 |
Neutral Messenger Stranding N/A 1 |
Neutral Messenger Rated Strength (lbs.) N/A 1970 |
Nominal Lay Length (inches) N/A 14.88 |
Weight (lb/1000 ft) XLP N/A 429 |
Weight (lb/1000 ft) Poly N/A 411 |
Allowable Ampacities XLP N/A 145 |
Allowable Ampacities Poly N/A 115 |
Caslon Caslon/Asset/CU-TRIPLEX-SERVICE-DROP.jpg |
Phase Conductor Size AWG N/A 4 |
Phase Conductor Stranding N/A 7 |
Phase Conductor Cover Thickness (mils) N/A 45 |
Neutral Messenger Size AWG N/A 4 |
Neutral Messenger Stranding N/A 7 |
Neutral Messenger Rated Strength (lbs.) N/A 1938 |
Nominal Lay Length (inches) N/A 14.88 |
Weight (lb/1000 ft) XLP N/A 432 |
Weight (lb/1000 ft) Poly N/A 413 |
Allowable Ampacities XLP N/A 145 |
Allowable Ampacities Poly N/A 115 |
Minion Minion/Asset/CU-TRIPLEX-SERVICE-DROP.jpg |
Phase Conductor Size AWG N/A 2 |
Phase Conductor Stranding N/A 7 |
Phase Conductor Cover Thickness (mils) N/A 45 |
Neutral Messenger Size AWG N/A 4 |
Neutral Messenger Stranding N/A 1 |
Neutral Messenger Rated Strength (lbs.) N/A 1970 |
Nominal Lay Length (inches) N/A 20.58 |
Weight (lb/1000 ft) XLP N/A 594 |
Weight (lb/1000 ft) Poly N/A 571 |
Allowable Ampacities XLP N/A 195 |
Allowable Ampacities Poly N/A 155 |
Primer Primer/Asset/CU-TRIPLEX-SERVICE-DROP.jpg |
Phase Conductor Size AWG N/A 2 |
Phase Conductor Stranding N/A 7 |
Phase Conductor Cover Thickness (mils) N/A 45 |
Neutral Messenger Size AWG N/A 4 |
Neutral Messenger Stranding N/A 7 |
Neutral Messenger Rated Strength (lbs.) N/A 1938 |
Nominal Lay Length (inches) N/A 20.58 |
Weight (lb/1000 ft) XLP N/A 596 |
Weight (lb/1000 ft) Poly N/A 574 |
Allowable Ampacities XLP N/A 195 |
Allowable Ampacities Poly N/A 155 |
Century Century/Asset/CU-TRIPLEX-SERVICE-DROP.jpg |
Phase Conductor Size AWG N/A 2 |
Phase Conductor Stranding N/A 7 |
Phase Conductor Cover Thickness (mils) N/A 45 |
Neutral Messenger Size AWG N/A 2 |
Neutral Messenger Stranding N/A 7 |
Neutral Messenger Rated Strength (lbs.) N/A 3050 |
Nominal Lay Length (inches) N/A 20.58 |
Weight (lb/1000 ft) XLP N/A 674 |
Weight (lb/1000 ft) Poly N/A 651 |
Allowable Ampacities XLP N/A 195 |
Allowable Ampacities Poly N/A 155 |
Corinthian Corinthian/Asset/CU-TRIPLEX-SERVICE-DROP.jpg |
Phase Conductor Size AWG N/A 1/0 |
Phase Conductor Stranding N/A 19 |
Phase Conductor Cover Thickness (mils) N/A 60 |
Neutral Messenger Size AWG N/A 1/0 |
Neutral Messenger Stranding N/A 7 |
Neutral Messenger Rated Strength (lbs.) N/A 4752 |
Nominal Lay Length (inches) N/A 20.58 |
Weight (lb/1000 ft) XLP N/A 1073 |
Weight (lb/1000 ft) Poly N/A 1036 |
Allowable Ampacities XLP N/A 265 |
Allowable Ampacities Poly N/A 205 |
Doric Doric/Asset/CU-TRIPLEX-SERVICE-DROP.jpg |
Phase Conductor Size AWG N/A 2/0 |
Phase Conductor Stranding N/A 19 |
Phase Conductor Cover Thickness (mils) N/A 60 |
Neutral Messenger Size AWG N/A 2/0 |
Neutral Messenger Stranding N/A 7 |
Neutral Messenger Rated Strength (lbs.) N/A 5926 |
Nominal Lay Length (inches) N/A 25.42 |
Weight (lb/1000 ft) XLP N/A 1342 |
Weight (lb/1000 ft) Poly N/A 1301 |
Allowable Ampacities XLP N/A 300 |
Allowable Ampacities Poly N/A 235 |