Type SHD-GC 3-Conductor EPR/CPE 15kv 100% Insulation Level - 90°C
Type SHD-GC (Portable Power)
Applications
This cable is designed for heavy-duty high voltage portable power applications on mobile equipment such as shovels, dredges, drilling ring, and underground mine power distribution where the delivery of a heavy power load and maximum safety is required.
Construction
Conforms to ICEA S-68-516 (NEMA WC8).Notes
This cable is designed for heavy-duty high voltage portable power applications on mobile equipment such as shovels, dredges, drilling ring, and underground mine power distribution where the delivery of a heavy power load and maximum safety is required.
Construction
- Conductor is extra flexible, stranded, tinned annealed copper.
- Insulation is Ethylene Propylene Rubber (EPR).
- Covered grounding and 8-gauge ground check conductors.
- Jacket is Black Chlorinated Polyethylene (CPE).
Conforms to ICEA S-68-516 (NEMA WC8).Notes
- Neoprene jacket optional.
- Shipping tolerance +/- 10%
Item # |
Power
|
Power
|
Power
|
Ground Wire
|
Ground Wire
|
Jacket
|
Overall
|
Net Weight
|
---|---|---|---|---|---|---|---|---|
DL01-15-2 DL01-15-2/ImgCustom/1006/placeholder_notavailable.gif |
Power Conductors Size AWG N/A 2 |
Power Conductors # of Strands N/A 133 |
Power Conductors Insulation Thickness N/A 210 Inches |
Ground Wire Size AWG N/A 6 |
Ground Wire # of Strands N/A 133 |
Jacket Thickness (Inches) N/A .235 |
Overall Diameter (inches) N/A 2.41 |
Net Weight Per MFT N/A 2950 Lbs |
DL02-15-1/0 DL02-15-1/0/ImgCustom/1006/placeholder_notavailable.gif |
Power Conductors Size AWG N/A 1/0 |
Power Conductors # of Strands N/A 259 |
Power Conductors Insulation Thickness N/A 210 Inches |
Ground Wire Size AWG N/A 4 |
Ground Wire # of Strands N/A 133 |
Jacket Thickness (Inches) N/A .250 |
Overall Diameter (inches) N/A 2.64 |
Net Weight Per MFT N/A 3650 Lbs |
DL03-15-2/0 DL03-15-2/0/ImgCustom/1006/placeholder_notavailable.gif |
Power Conductors Size AWG N/A 2/0 |
Power Conductors # of Strands N/A 259 |
Power Conductors Insulation Thickness N/A 210 Inches |
Ground Wire Size AWG N/A 3 |
Ground Wire # of Strands N/A 133 |
Jacket Thickness (Inches) N/A .250 |
Overall Diameter (inches) N/A 2.73 |
Net Weight Per MFT N/A 4250 Lbs |
DL04-15-4/0 DL04-15-4/0/ImgCustom/1006/placeholder_notavailable.gif |
Power Conductors Size AWG N/A 4/0 |
Power Conductors # of Strands N/A 259 |
Power Conductors Insulation Thickness N/A 210 Inches |
Ground Wire Size AWG N/A 1 |
Ground Wire # of Strands N/A 259 |
Jacket Thickness (Inches) N/A .265 |
Overall Diameter (inches) N/A 3.05 |
Net Weight Per MFT N/A 5930 Lbs |