Type SHD-GC 3-Conductor EPR/CPE 2kV 100% Insulation Level - 90°C
Type SHD-GC (Portable Power)
Applications
This cable is designed for heavy-duty high voltage portable power trailing cable between the load center and equipment such as power shovels, draglines, and other excavators and is suitable for use in open pit mines, quarries and on gantry cranes where the delivery of a heavy power load and maximum safety is required.
Construction
Conforms to ICEA S-68-516 (NEMA WC8).
Notes
This cable is designed for heavy-duty high voltage portable power trailing cable between the load center and equipment such as power shovels, draglines, and other excavators and is suitable for use in open pit mines, quarries and on gantry cranes where the delivery of a heavy power load and maximum safety is required.
Construction
- Conductor is extra flexible, stranded, tinned annealed copper.
- Insulation is Ethylene Propylene Rubber (EPR).
- Covered grounding and 8-gauge ground check conductors.
- Jacket is Black Chlorinated Polyethylene (CPE).
Conforms to ICEA S-68-516 (NEMA WC8).
Notes
- Neoprene jacket optional.
- Shipping tolerance +/- 10%
Item # |
Power
|
Power
|
Power
|
Ground Wire
|
Ground Wire
|
Jacket
|
Overall
|
Net Weight
|
---|---|---|---|---|---|---|---|---|
DL01-5-6 DL01-5-6/ImgCustom/1006/placeholder_notavailable.gif |
Power Conductors Size AWG N/A 6 |
Power Conductors # of Strands N/A 133 |
Power Conductors Insulation Thickness N/A .110 Inches |
Ground Wire Size AWG N/A 10 |
Ground Wire # of Strands N/A 49 |
Jacket Thickness (Inches) N/A .185 |
Overall Diameter (inches) N/A 1.56 |
Net Weight Per MFT N/A 1460 Lbs |
DL05-5-4 DL05-5-4/ImgCustom/1006/placeholder_notavailable.gif |
Power Conductors Size AWG N/A 4 |
Power Conductors # of Strands N/A 133 |
Power Conductors Insulation Thickness N/A .110 Inches |
Ground Wire Size AWG N/A 8 |
Ground Wire # of Strands N/A 133 |
Jacket Thickness (Inches) N/A .185 |
Overall Diameter (inches) N/A 1.68 |
Net Weight Per MFT N/A 1690 Lbs |
DL03-5-5 DL03-5-5/ImgCustom/1006/placeholder_notavailable.gif |
Power Conductors Size AWG N/A 2 |
Power Conductors # of Strands N/A 259 |
Power Conductors Insulation Thickness N/A .110 Inches |
Ground Wire Size AWG N/A 6 |
Ground Wire # of Strands N/A 133 |
Jacket Thickness (Inches) N/A .205 |
Overall Diameter (inches) N/A 1.87 |
Net Weight Per MFT N/A 2290 Lbs |
DL04-5-1/0 DL04-5-1/0/ImgCustom/1006/placeholder_notavailable.gif |
Power Conductors Size AWG N/A 1/0 |
Power Conductors # of Strands N/A 266 |
Power Conductors Insulation Thickness N/A .110 Inches |
Ground Wire Size AWG N/A 4 |
Ground Wire # of Strands N/A 133 |
Jacket Thickness (Inches) N/A .220 |
Overall Diameter (inches) N/A 2.08 |
Net Weight Per MFT N/A 3110 Lbs |
DL05-5-5/0 DL05-5-5/0/ImgCustom/1006/placeholder_notavailable.gif |
Power Conductors Size AWG N/A 2/0 |
Power Conductors # of Strands N/A 342 |
Power Conductors Insulation Thickness N/A .110 Inches |
Ground Wire Size AWG N/A 2 |
Ground Wire # of Strands N/A 133 |
Jacket Thickness (Inches) N/A .220 |
Overall Diameter (inches) N/A 2.20 |
Net Weight Per MFT N/A 3570 Lbs |
DL06-5-4/0 DL06-5-4/0/ImgCustom/1006/placeholder_notavailable.gif |
Power Conductors Size AWG N/A 4/0 |
Power Conductors # of Strands N/A 532 |
Power Conductors Insulation Thickness N/A .110 Inches |
Ground Wire Size AWG N/A 1 |
Ground Wire # of Strands N/A 259 |
Jacket Thickness (Inches) N/A .235 |
Overall Diameter (inches) N/A 2.50 |
Net Weight Per MFT N/A 4990 Lbs |
DL07-5-550 DL07-5-550/ImgCustom/1006/placeholder_notavailable.gif |
Power Conductors Size AWG N/A 250 |
Power Conductors # of Strands N/A 427 |
Power Conductors Insulation Thickness N/A .120 Inches |
Ground Wire Size AWG N/A 1/0 |
Ground Wire # of Strands N/A 259 |
Jacket Thickness (Inches) N/A .250 |
Overall Diameter (inches) N/A 2.69 |
Net Weight Per MFT N/A 5820 Lbs |
DL08-5-350 DL08-5-350/ImgCustom/1006/placeholder_notavailable.gif |
Power Conductors Size AWG N/A 350 |
Power Conductors # of Strands N/A 427 |
Power Conductors Insulation Thickness N/A .120 Inches |
Ground Wire Size AWG N/A 2/0 |
Ground Wire # of Strands N/A 259 |
Jacket Thickness (Inches) N/A .265 |
Overall Diameter (inches) N/A 2.95 |
Net Weight Per MFT N/A 7540 Lbs |
DL09-5-500 DL09-5-500/ImgCustom/1006/placeholder_notavailable.gif |
Power Conductors Size AWG N/A 500 |
Power Conductors # of Strands N/A 427 |
Power Conductors Insulation Thickness N/A .120 Inches |
Ground Wire Size AWG N/A 4/0 |
Ground Wire # of Strands N/A 259 |
Jacket Thickness (Inches) N/A .280 |
Overall Diameter (inches) N/A 3.31 |
Net Weight Per MFT N/A 9840 Lbs |